Generac 5500Xl Generator Parts
GENERAC POWER SYSTEMS POWERBOSS 5. STORM PLUS OWNERS MANUAL Pdf Download. It is used to alert you to potential personal injury hazards. Obey all safety messages Questions Help is just a moment away Call Generac Generator Helpline 1 8. M F 8 5 CT Web www. Every effort hasbeen madeto ensure that informationin Turn generator OFF and let it cool at east. However, Generac removing gas cap. Nokia 700 Adobe Reader. Loosen cap slowly to relieve pressure in tank reserves the right to change,alter or otherwise improvethe Fill fuel tank outdoors. Generac 5500Xl Generator Parts' title='Generac 5500Xl Generator Parts' />DANGER Use generator only for intended uses. Generac generator helpline at 1 8. Operate generator only on level surfaces. Do not expose generator to excessive moisture, dust, dirt, or corrosive vapors. Generac 5500Xl Generator Parts' title='Generac 5500Xl Generator Parts' />Home emergency backup electric power portable generator generators installation hookup and connection. House wiring. Testing Procedure. Field flash procedure. KNOWYOUR GENERATOR Read this owners manual and safety rules before operating your generator. Compare the illustrationswith your generator,to familiarize yourself with the locationsof various controts and adjustments. Savethis manualfor future reference. Fuel. Tank Spark. Run your Generac Generator on propane or natural gas with a doityourself change over kit from US Carburetion. Arrester Muffler Choke Lever Circuit AC Breakers Air Cleaner 1. Volt AC, 3. 0 Amp Receptacle. Your g enerator requires some assembly and isready f or CARTON CONTENTS useafterit has been properly s erviced withthe Check all contents. If any parts are missing or damaged,call recommended oiland fuel. If you have any problems with the assembly of your. Slide a wheel over the axle. GN-SmFrm_GovRod.png' alt='Generac 5500Xl Generator Parts' title='Generac 5500Xl Generator Parts' />View and Download Generac Power Systems 4000EXL owners manual online. BRJGGS STRATTON. 4000EXL Portable Generator pdf manual download. Find great deals for Generac Power Regulator Part 84132GS. Shop with confidence on eBayAdd Gasoline NOTE Be sure to installboth wheels with the air pressure valve on the outboard side. ARNING Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. Allow Retain wheel on axle with the retaining pin. You may unit to cool for two minutes before refueling. GROUNDING Turn the fuel valve to the On position Figure 4. G EN ERATO R The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground. Local electrical codes may also require proper grounding of the unit. This receptacle powers 1. Volt AC, 6. 0 Hz, single Connecting Electrical Loads phase loads requiring up to 5,5. W Let engine stabilize and warm up for a few minutes after at 3. Amps for 1. 20. Volts or 2. Volts. The outlet is starting. DONT OVERLOAD YOUR Plug in and turn on the next load. Again, permit the generator to stabilize. G EN ERATO R Repeat steps 4 and 5 for each additional load. Never add more loadsthan the generator capacity. Take special care to consider surge loads in generator capacity, Capacity as described above. SPECIFICATIONS Generator Maintenance Generator maintenance consists of keeping the unit clean Maximum Surge. Watts. 8,5. 00 watts and dry. Operate and store the unit in a clean dry Continuous Wattage Capacity. Power Factor STO RAG E AUTIONStorage covers can be flammable. Oo Not place a storage cover over a hot The generator should be started at least once every seven generator. Let the unit cool for a sufficient time days and allowed to run at least 3. If this cannot before placing the cover on the unit. View and Download Generac Power Systems PowerBOSS 5500 StormPlus owners manual online. Briggs Stratton. PowerBOSS 5500 StormPlus Portable Generator pdf manual. Search titles only has image posted today bundle duplicates include nearby areas birmingham, AL bhm bowling green, KY blg. The A and C Kit section has three main pages. You are currently at A C Kit List Page application list by generator andor engine Use these links to learn more. Connect another device that is in good no AC output condition. Fault in generator. Contact Generac service facility. Short circuit in a connected load. Disconnect shorted electrical load. Generator is overloaded. SeeDont Overload the Generator on Engine runs good but page. NOTES. SCHEMATIC BRIOGE RECTIFIER BLUE6 EXCITATION FIELD BLUE GRAY 4. GR4. Y BLUE ii 2. C. B. 4. 44 BLUE 1. V2. 04 GRAY BLUE 2. BLUE 2. 2 I1. BLUE 1. BLUE I1. 4 GR4. Y 2. WIRING DIAGRAM CIRCUIT CIRCUIT BREAKER BREAKER 4. A 4. 4A 1. 202. IBOV 2. CARNING TAB MUST NOT BE BROKEN RED BLUE 2. SIX LUG CONNECTOR HOUSINO HBUSING Bl. X LUO CONNECTOR NOTE POSITIVE BRUSH IS CLOSEST TO BEARING BLUE CUSTOMER GRBUNB LUO. EXPLODED VIEW MAIN UNIT. PARTS LIST MAIN UNIT Item Part Description Item Part Description B1. GS CRADLE B2. 15. GS SCREW, I 0 Self Drilling B9. GS 1. 89. 15. 5GS WASHER, Flat, 6. SUPPORT,Engine B9. GS 1. 88. 97. 3GS GROMMET,Tank SUPPORT,Engine Muffler 6. GGS 1. 89. 15. 6GS HHCS, M6 1. HOUSING, Engine. Adapter 1. GS 8. 02. 70. GS. EXPLODEDVIEWAND PARTS LIST WHEEL Item Pa. X Qty Description B4. GS ASSEMBLY, H andle BI7. GS LEG, Mounting 5. GS NUT, Locking Hex M8 1. GS HHCS, M8 1. 2. HGS AXLE B4. 96. 6GS WHEEL, 1. Diameter 8. 70. 05. AGS PIN, Retaining 2. GS WASHER, Flat 4. GS HHCS, M8 1. 2. EXPLODED VIEW AND PARTS LIST CONTROL PANEL Item Part Qty Description 1. GS COVER, Lid, Control Panel 1. GS CONTROL PANEL,Compact 1. GS CLIP,Hinge Pin Retainer 1. GS SPRING, Hinge, Pin 1. GS PIN, Hinge, Cover, Compact 6. GS OUTLET, 1. 20. V,2. 0Amp, Duplex 1. GS NUT, Patnut,Pushnut,53. GS CAP, Circuit Breaker 7. GS. AIIADA COMBUSTIBLE informacibnque aparece en este manual es exacta y se encuentra actualizada. Sin embargo, Generac se reserva el derecho a Apague el generador posicibn OFF y djelo enfriar al menos por cambiar, alterar o de otra manera mejorar, el producto y este 2 minutos antes de remover la tapde la gasolina. Afloie atapa. Use el generador solamente con la finalidadpara el cual rue disefiado. Si usted tiene alguna pregunta acerca de las finalidadesde uso del generador, preg. Generac. Opere el generdor solamente en superficies niveldas. No exponga al generador a una humedad excesiva, polvo, suciedad o vapores corrosivos. CONOZCA SU GENERADOR LEA ESTE MANUAL DEL PROPIETARIOY LAS REGLAS DE SEGURIDAD ANTES DE OPERAR SU GENERADOR. Compare las ilustraciones con su Generador para familiarizarse con las ubicaciones de los diferentes controles y ajustes. Conserve este manual para referencias futuras. Tanque de Combustible Silenciador Apagachispas. Su generador requiere de ciertos procedimientos de montaje y La unidad principal solo estar listo para ser utilizado despus de haberle Manual del propietario suministrado servicio con el combustible y aceite recomendados. Aceite para motor Si usted tiene problemas con el montaje de su generador, por Tapones de fijaci. Ilame a la Ifnea de ayuda para generadores al 1 8. Repita lospasos 3y. Remuevalos bloques temporales. ADVERTENCl. A No Ilene excesivamente el tanque de combustible. Deje suficiente espacio para la expansi. Para a yudar alensamblaje delapata deapoyo, haga descansar elgenerador enlacamilla conlaparte del m otor Use gasolina regular SIN CONTENIDO DE PLOMO hacia a bajo. Anexe. CONEXION ATIERRA GENERADOR El C6digo Nacional de Electricidad exige que el marco y las partes exteriores del generador conductoras de electricidad, estn conectadas a tierra adecuadamente. Los c. 6digos elctricos locales tambin pueden exigir que la unidad est. Para tal prop. 6sito, se ha instalado una tuerca mariposa para conexi. Rgura 1. 2. Conexion De Cargas Electricas Deje que el motor se estabilice y se caliente por unos minutos despusdel arranque. Juego de Cable de 4 Alambres Conecte y encienda las cargas elctricas de 1. Voltios AC monofsicas de 6. Hz que desse. No conecte cargas de 2. Voltios a tomacorrientes de 1. Voltios. NO SOBRECARGUE Conecte y encienda la pr. De nuevo, permita que el generador se estabilice. GENERADOR Repita los pasos. Capacidad Nunca ahada ms cargas sobre la capacidad del generador. Tome Usted debe asegurarse que su generador puede proveer el una atenci. ESPECIFICACl. ONES enfriamiento, algo del agua quedar retenida en los espacios vactos y grietas del aislamiento del devanado del estator y rotor.